Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Infect Chemother ; 29(6): 586-591, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849098

RESUMO

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, a rapid and reliable point-of-care test is an essential tool for controlling the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In particular, an immunochromatography test (ICT) that uses saliva specimens for rapid antigen detection not only reduces the risk of secondary infections but also reduces the burden on medical personnel. METHODS: The newly developed salivary antigen test kit "Inspecter Kowa® SARS-CoV-2" is an ICT to which saliva specimens can be directly applied. We evaluated its usefulness in comparison with reverse transcription quantitative PCR (RT-qPCR) and the Espline® SARS-CoV-2 Kit for the detection of SARS-CoV-2 using nasopharyngeal swab specimens. In this study, 140 patients with suspected symptomatic COVID-19 who visited our hospital were enrolled, and nasopharyngeal swab and saliva specimens were collected after they consented to participate in the study. RESULTS: Inspector Kowa SARS-CoV-2 was positive in 45 of 61 (73.8%) saliva that were positive by RT-qPCR and the Espline® SARS-CoV-2 Kit was also positive in 56 of 60 (93.3%) Np swabs that were positive by RT-qPCR. Good antigen detection was achieved by ICT with saliva and nasopharyngeal swab specimens when viral load was ≥105 copies/mL, whereas detection sensitivity was low when viral load was <105 copies/mL, especially in saliva specimens. CONCLUSION: This ICT for the detection of SARS-CoV-2 salivary antigen is an attractive tool that does not require specialized equipment and allows patients to perform the entire process from sample collection to self-diagnose and to reduce the burden on medical care during a pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Manejo de Espécimes/métodos , Nasofaringe
3.
Anal Chem ; 94(10): 4218-4226, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35238540

RESUMO

The most common diagnostic method used for coronavirus disease-2019 (COVID-19) is real-time reverse transcription polymerase chain reaction (PCR). However, it requires complex and labor-intensive procedures and involves excessive positive results derived from viral debris. We developed a method for the direct detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swabs, which uses matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-ToF MS) to identify specific peptides from the SARS-CoV-2 nucleocapsid phosphoprotein (NP). SARS-CoV-2 viral particles were separated from biological molecules in nasopharyngeal swabs by an ultrafiltration cartridge. Further purification was performed by an anion exchange resin, and purified NP was digested into peptides using trypsin. The peptides from SARS-CoV-2 that were inoculated into nasopharyngeal swabs were detected by MALDI-ToF MS, and the limit of detection was 106.7 viral copies. This value equates to 107.9 viral copies per swab and is approximately equivalent to the viral load of contagious patients. Seven NP-derived peptides were selected as the target molecules for the detection of SARS-CoV-2 in clinical specimens. The method detected between two and seven NP-derived peptides in 19 nasopharyngeal swab specimens from contagious COVID-19 patients. These peptides were not detected in four specimens in which SARS-CoV-2 RNA was not detected by PCR. Mutated NP-derived peptides were found in some specimens, and their patterns of amino acid replacement were estimated by accurate mass. Our results provide evidence that the developed MALDI-ToF MS-based method in a combination of straightforward purification steps and a rapid detection step directly detect SARS-CoV-2-specific peptides in nasopharyngeal swabs and can be a reliable high-throughput diagnostic method for COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Lasers , Nasofaringe , RNA Viral/genética , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
4.
J Med Virol ; 93(12): 6778-6781, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34170555

RESUMO

A high-throughput, fully automated antigen detection test for SARS-CoV-2 is a viable alternative to reverse-transcription polymerase chain reaction (RT-qPCR) for mass screening during outbreaks. In this study, we compared RT-qPCR for viral load and the VITROS® SARS-CoV-2 Antigen Test with reference to the results of the LUMIPULSE® SARS-CoV-2 Ag Test. Of 128 nasopharyngeal swab specimens taken from patients suspected of being infected with SARS-CoV-2, 49 were positive and 79 were negative according to RT-qPCR. Consistent dose-dependent detection with VITROS® assay was successfully achieved when using nasopharyngeal swab specimens with Ct values of 32.0 or lesser, whereas the CLEIA-based LUMIPULSE® assay was able to detect lower viral loads compared with the VITROS® assay. Our results show that the performance of the VITROS® assay was satisfactory for the diagnosis of contagious COVID-19 patients in the clinical setting. Highlights The performance of the VITROS® SARS-CoV-2 Antigen Test was sufficient for the diagnosis of contagious COVID-19. This test showed high sensitivity and specificity in the detection of SARS-CoV-2 in samples with a Ct value of 32 or less.


Assuntos
Teste Sorológico para COVID-19/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Técnicas Imunoenzimáticas/métodos , Testes Imunológicos/métodos , SARS-CoV-2/imunologia , Antígenos Virais/genética , Antígenos Virais/imunologia , COVID-19/virologia , Humanos , Programas de Rastreamento/métodos , Nasofaringe/imunologia , Nasofaringe/virologia , RNA Viral/genética , RNA Viral/imunologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade , Carga Viral/genética , Carga Viral/imunologia
5.
Diagn Microbiol Infect Dis ; 100(3): 115370, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33744623

RESUMO

Several automated high-throughput immunoassays for detecting anti-SARS-CoV-2 antibodies by a semi-quantitative approach have been commercialized. In this study, we describe the timeline of the antibody response in patients with RT-PCR-confirmed COVID-19. A total of 292 sequential serum samples from 33 Japanese patients were retrospectively analyzed using four test kits for SARS-CoV-2: the Abbott SARS-CoV-2 IgG assay (Abbott), Elecsys® Anti-SARS-CoV-2 assay (Roche Diagnostic), and VITROS® Anti-SARS-CoV-2 Total and IgG assays (Ortho Clinical Diagnostics). All automated immunoassays could equivalently identify positive sera collected within 2 weeks after symptom onset (99.3%-100%). In addition, the S protein-based automated immunoassay, the VITROS® Anti-SARS-CoV-2 Total assay, may play a complementary role in evaluating passive antibody therapies or vaccines against SARS-CoV-2, although further research is required.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/imunologia , Adulto , Idoso , COVID-19/imunologia , Feminino , Ensaios de Triagem em Larga Escala , Humanos , Imunoensaio , Cinética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
7.
Bone ; 138: 115469, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32512165

RESUMO

The human ACVR1 gene encodes a transmembrane protein consisting of 509 amino acids called activin A receptor, type I (ACVR1) or activin receptor-like kinase 2 (ALK2) and has nine coding exons. The ALK2 protein functions as a signaling receptor for ligands of the transforming growth factor-ß family. In the human ACVR1 gene, approximately 20 types of heterozygotic mutations in the coding exons have been associated with congenital disorders and somatic cancer, such as fibrodysplasia ossificans progressiva (FOP), diffuse intrinsic pontine glioma, diffuse idiopathic skeletal hyperostosis and some congenital heart disorders. In the present study, we designed primers for direct sequencing of the nine coding exons in the human ACVR1 gene. The reliability of the primers was examined by PCR and DNA sequencing using genomic DNA prepared from peripheral blood or swab samples of three patients with FOP who had different mutations in the ACVR1 gene. A single nucleotide heterozygotic mutation was identified in each genomic sample without additional mutations in other regions. Therefore, the primers designed for the nine coding exons of the ACVR1 gene could be useful for the genetic diagnosis of patients who may have disorders associated with mutations in the ACVR1 gene.


Assuntos
Receptores de Ativinas Tipo I , Primers do DNA , Éxons , Miosite Ossificante , Receptores de Ativinas Tipo I/genética , Heterozigoto , Humanos , Mutação/genética , Miosite Ossificante/genética , Reprodutibilidade dos Testes , Análise de Sequência de DNA
8.
J Clin Virol ; 129: 104446, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32512376

RESUMO

With the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), there is an urgent need for more rapid and simple detection technologies at the forefront of medical care worldwide. In this study, we evaluated the effectiveness of the Loopamp® 2019-SARSCoV-2 Detection Reagent Kit, which uses loop-mediated isothermal amplification (LAMP) technology. In this protocol, cDNA is synthesized from SARS-CoV-2 RNA using reverse transcriptase, followed by DNA amplification under isothermal conditions in one step. The RT-LAMP test kit amplified the targeted RNA of a SARS-CoV-2 isolate with a detection limit of 1.0 × 101 copies/µL, which was comparable to the detection sensitivity of quantitative reverse transcription PCR (RT-qPCR). Comparison with the results of RT-qPCR for 76 nasopharyngeal swab samples from patients with suspected COVID-19 showed a sensitivity of 100 % and a specificity of 97.6 %. In the 24 RNA specimens derived from febrile Japanese patients with or without influenza A, no amplification was observed using RT-LAMP. RT-LAMP could be a simple and easy-to-use diagnostic tool for the detection of SARS-CoV-2.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Pneumonia Viral/diagnóstico , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Humanos , Japão , Pandemias , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo
9.
Anal Sci ; 30(4): 519-22, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24717664

RESUMO

The preparation and application of a stop and go extraction tip (StageTip) used for pre-purification of sample solutions for LC-MS/MS analysis of DNA adducts was simplified and improved to increase throughput while maintaining high adduct selectivity. It was demonstrated that the StageTip composed of two sheets of a poly(styrene-divinylbenzene) copolymer disk could be easily prepared and proved useful for selective extraction of trace amounts of DNA adducts from a sample solution containing a great quantity of normal deoxynucleosides.


Assuntos
Métodos Analíticos de Preparação de Amostras/métodos , Cromatografia Líquida de Alta Pressão/métodos , Adutos de DNA/análise , Espectrometria de Massas em Tandem/métodos , Métodos Analíticos de Preparação de Amostras/instrumentação , Fracionamento Químico , Cromatografia Líquida de Alta Pressão/instrumentação , Desoxirribonucleosídeos/química , Ensaios de Triagem em Larga Escala , Poliestirenos/química , Sensibilidade e Especificidade , Soluções , Espectrometria de Massas em Tandem/instrumentação
10.
Rinsho Byori ; 58(12): 1188-92, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21344794

RESUMO

UNLABELLED: Tacrolimus monitoring is essential because tacrolimus has a narrow therapeutic dose range. A 35-year-old male after kidney transplantation showed unusually high tacrolimus concentrations in the affinity column mediated immunoassay (ACMIA). METHODS: His whole blood tacrolimus concentrations were measured by the ACMIA, microparticle enzyme immunoassay (MEIA), enzyme-linked immunosorbent assay (ELISA), and the enzyme multiplied immunoassay technique (EMIT). Since the findings were discrepant, the possible causes were investigated. To screen for endogenous beta-galactosidase, the cyclosporin A concentration of the patient's sample was measured by ACMIA. To determine whether the false increase was attributable to his plasma, tacrolimus concentrations were measured in the whole blood and plasma of the patient in question and 3 other patients. To eliminate heterophilic antibodies, the patient's plasma was treated with heterophilic blocking tube. To eliminate immunoglobulin interference, the patient's plasma was incubated with Protein A or G. RESULTS AND DISCUSSION: The patient's tacrolimus concentration was found to be 16.4, 3.7, 3.2, and 3.0 microg/L by the ACMIA, MEIA, ELISA, and EMIT, respectively. In the cyclosporin assay, the absorbance did not increase; therefore, beta-galactosidase participation was ruled out. Tacrolimus is mainly sequestered in erythrocytes; however, this patient's plasma and whole blood showed similar tacrolimus levels. Heterophilic blocking tube did not affect the patient's tacrolimus level. His tacrolimus concentration was reduced after incubation with Protein A, indicating that immunoglobulins trapped by Protein A had non-specifically interfered with the assay system. CONCLUSION: When the tacrolimus level indicated by the ACMIA is unexpectedly high, the patient's plasma should be assayed. If the tacrolimus plasma level is subsequently found to be high, the original result might be incorrect, and it is recommended that another method be used.


Assuntos
Imunoensaio/métodos , Tacrolimo/sangue , Adulto , Monitoramento de Medicamentos/métodos , Reações Falso-Positivas , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...